Timing On & Off With Clock Timers
This circuit uses two Kuhnke 54 series clock face timers to cycle a pneumatic cylinder. Each clock timer is independently set so that the outstroke time and rest time will be different. This basic circuit shows only the directional control valve and excludes any flow regulators or stop/start buttons that may be required. The download includes two circuits of which this application is circuit 2.
General
This circuit enables the user to select any one of the six time ranges available from the Kuhnke 54 series timer range.
Parts List
Our pneumatic circuits show valve numbers and codes for timers, counters, flow regulators etc. A valve table is shown as a seperate download. In this we identify the different possibilities for each valve code. We include push button operated spring return valves with colour alternatives, main pilot / spring return valves with G1/8 or G1/4 ports and so on. Our detail extends to protective covers, exhaust silencers and pneumatic fittings. The circuit parts lists do not include the cylinder, tubing or enclosure, all of which we would be pleased to quote for on request.