/ Register

Front Back

Predetermining Counters - Subtracting

Kuhnke Predetermining Subtracting Pneumatic Counters show one line of display

You set your starting display by using the mechanical push buttons. Pnuematic pulses are counted and the display then counts down from your predetermined start, to zero. A pneumatic output is then generated, which remains "on" until reset. There are 2 models to choose from in this range. Each is panel mounted with a manual reset button on the front that can be locked out.

Choose between a 3 digit or 5 digit display

Protective covers are available.

Features

  • Panel mounting
  • 3 or 5 digit display
  • Manual / pneumatic reset or
  • Manual / automatic reset
  • Convenient button setting
  • M5 connections
  • Maintenance free
  • Simple, fast and tidy installation
  • Light and durable
Data Specifications
Operating Pressure & Temp2 - 8 bar 0 ... + 60°c
Air QualityOil Free & Dry 5micron filtered
ConnectionsM5 ports
4mm push in option
Display [single line]3 or 5 digit 4mm height
Reset [Standard]Manual via button or pneumatic signal
Reset Pulse180ms minimum Max 1 per 2s
IP RatingIP40, IP55 with cover
Count Pulse8ms min. Max 20Hz
MountingPanel mount
Downloads
Predetermining Counters - Subtracting
498Kb
Part Numbers
50.685 (0.497.530) 3 digit subtracting counter
M5 ports
50.690 (0.497.550) 5 digit subtracting counter
M5 ports
Accessories
1.405.613 Protective cover IP55 with knob
1.405.614 Protective cover IP55 with lock
Related Products
Pneumatic Valves & Fittings
Pneumatic Sensor